Samples of water (effluent) are taken after passage through the units at predetermined times and tested for their microbiological, chemical or particulate concentration. These concentrations are compared with those of the influent water and assessed for their log reduction, acceptance criteria is also dependant upon the manufacturer’s claims.
SAMPLE REQUIREMENTS:
Duplicate set of units required for each testing (filter jugs). For filtration units, provide 2 units with replacement cartridges for each type of test. All in-let and out-let hoses must also be provided with the units if applicable. Consult the laboratory prior to sending samples for testing.
TURNAROUND TIMES:
Sample collection period depends on the performance claim of each product. Assay of sample extracts, after collection , is ~3 weeks.
test protocols:
|
Test Description
|
Test code
|
Turnaround Time
|
| Test drinking water Treatment Units for Bacteriostatic properties |
AS/NZS 4348; App. A
AMS; TM - 300
?xml:namespace> |
Dependent on performance claim of product
|
|
Testing drinking Water Treatment Units for Chemical reduction claims
|
AS/NZS 4020; App. B
AMS; TM - 301
?xml:namespace> |
Dependent on performance claim of product
|
|
Testing drinking Water Treatment Units for Turbidity & Cyst reduction claims
|
AS/NZS 4020; App. C
AMS; TM - 302
?xml:namespace> |
Dependent on performance claim of product
|
|
Testing drinking Water Treatment Units for Taste, Odour & Chlorine reduction claims
|
AS/NZS 4020; App. D
AMS; TM - 303
?xml:namespace> |
Dependent on performance claim of product
|